Yueqing long road electric co.,Ltd

3 Uninterruptable Power Supply(UPS)

Category:- UPS & EPS

Tel:+0086.577.61566899

Address:No#221,Wei 17 ROAD,Economic Develop Zone YueQing CITY ZHEJIANG PROVINCE ,CHINA

Intro: Back-up UPS is a technically-modified new product of the company on the basis of the previousUPS-500VA one and has multifunction as automatic voltage regulation of local electricity,sychronous switches for users load,protections of over-voltage,overvoltage,overcurrent,over-charge of batterise,feed and so on.


Detail

Messages

Product Detail:

Application

Back-up UPS is a technically-modified new product of the company on the basis of the previousUPS-500VA one and has multifunction as automatic voltage regulation of local electricity,sychronous switches for users load,protections of over-voltage,overvoltage,overcurrent,over-charge of batterise,feed and so on.

ProductOn Line UPS parallel Redundancy (6~10kVA 1Ph/1Ph)
TypeG6KNG10KNG6KNSG10KNS
Rated powerVA/W6kVA/4.2kW10kVA/4.2kW6kVA/4.2kW10kVA/4.2kW
InputNominal voltage220VAC (or 230/240VAC)
Voltage range176~276VAC
Frequency range46~54Hz
PhaseSingle Pahse
Power factor0.98
ConnectionHardwirde
OutputVoltage220VAC±1% (or 230/240VAC±1%)
Frequency50Hz±1%(Battery mode)
Wave formSine wave
Power factor0.7
Voltage distortion2% under liner load
Overload capability105%~130% for 10min,≥130% for 1s.
Current crest ratio3:1 max
ConnectionsHardwired
BatteryTypeSealed,Maintenance free, Lead-Acid
Quantity20 piecesDepends on the requested back-up time
Nominal voltage240 VDC
Back-up time(full load)7min5minDepends on the capacity of the external battery bank
Recharge time8 hrs to 90% of capacity after full load dischargeDepends on the capacity of the external battery bank
ConnectionExternal Battery Socket
Transfer time0 ms
Maintenance bypass switchYes
LED indicatorsStatusLoad level/Battery level.Utility power,Inverter,Bypass, Overload.Fault
Audible alarmBypassAlarm beeps every two minutes
Battery dischargeAlarm beeps every four seconds, Every second if battery low
OverloadAlarm beeps two for every second
FaultAlarm beeps continuously
Acoustic NoiseAt 1 meter distance≤55 dB
CommunicationDB-9 portRS232 serial interface
Intelligent slotOptions: SNMP Card, AS400 Card or Winpower CMC/(USB-Port)
Parallel Port
Up to three units in parallel for power redundancy and load sharing
EnvironmentalOperating temperature0~40oC
Operating humidity20~90% non-condensing
WeightNet(kg)84933538
Dismensions W×L×H (mm)260×570×717